Proton Power Control Pvt Ltd.
Pimple Nilakh, Pune, Maharashtra
Send E-mail
Send SMS
Home»Products»

AC Controller

Leading Manufacturer of air conditioning controller, dual ac controller, 2 ac controller, 2 a/c controller with gsm, 3 ac controller gsm based and space maker ac controller from Pune.

REQUEST CALLBACK
Approx. Rs 1,500 / Unit/Onwards
Get Best Quote
Our company endeavors to reach excellence by providing premium quality Air Conditioning Controller that is also used to protect Air Conditioners from over load/under load, under/over voltage, HP/LP, Fire caused by fluctuated electricity. Offered conditioning controller is used to control A/Cs and maintain the temperature of the room with an accuracy of 0.1 C by automatic measurement of Room temperature and accordingly controlling A/C on/Offs. This conditioning controller is accessible in diverse specifications to choose from.

Features:

  • Precise Room temperature control
  • UV, OV, OL, UL protection
  • Password protected
  • Under load & over load protection

Other Details:

  • HP/LP (Optional)
  • 2x16 LCD display to view temperature, voltage, current, fault status & set points
  • Fire protection (Optional)
  • Separate output for fans & compressor
  • Humidity display & alarm (Optional)
  • Cyclic operation for equal run time of all A/cs
  • Fault log history
  • PC interfacing (Optional)
  • Detection of faulty A/c & automatic change over
  • Display of status & faults on LCD
  • Flexibility in using number of compressors
  • RTC fault history (Optional)

Yes! I am interested
REQUEST CALLBACK
Approx. Rs 1,500 / Unit/Onwards
Get Best Quote
Leveraging on our industrial experience, we have also been able to manufacture a wide range of Dual AC Controllers that are capable of controlling two Air Conditioners at a time. These are provided with separate Phase supply for both the ACs and control by pass features too.

Salient Features:

  • Controls two air conditioners
  • Separate Phase Supply for each A/C
  • Bright Red 4 Digit LED Display
  • Accurate Temperature sensing by precise temperature sensor
  • Time Sharing for Compressors to share load equally
  • Voltage & Current protections for each compressor
  • Separate alarm relay contacts for AC Fail
  • Separate alarm relay contacts for Room High
  • Hour counters for Compressor ON Period to check its reliability
  • Display of all the A/C parameters & fault messages continuously in a scrolling manner
  • Display Hold Feature
  • Password Protection for all the settings
  • Sensor Fail Mode to keep ON & OFF cycle of one of the time settings
  • Auto (with all protections)/Manual (without protection) Modes
  • Controller Bypass feature by provision of Switch on Front Panel
  • LED Indications to observe the status

Technical Specifications:


  • Supply Voltage: 230 VAC, 50 Hz +/- 15% separate for each A/C
  • Contact Rating: 30 A at 230 VAC for Compressor Live Outputs & 5 A at 250 VAC for Alarm Potential Free Outputs (C,N/O)
  • Temperature Sensor: Thermistor Sensor NTC 10K@25 C Metal body with clamp
  • Sensor Cable Length: 2.75 meters
  • Temperature Sensing Range: 0.0 C to 55.0 C
  • Resolution: 1V for Voltage, 0.1 A for Current & 0.1 C for temperature
  • Auto/Controller Bypass Switch: To bypass the controller i.e. A/C1 & A/C2 will remain ON continuously if both the switches are in ON condition
  • Mounting: Wall mounting
  • Size: 230 mm (H) X 225 mm (W) X 100 mm (D)

Yes! I am interested
REQUEST CALLBACK
Approx. Rs 1,500 / Unit
Get Best Quote
Our organization has successfully expanded its business in market owing to the offered elevated quality array of 2 Aircon Time Temp. This product is proportional type temperature controller used in combination with a control motor for proportional control of heating or cooling control valves or dampers. Offered product is designed by our competent professionals using finest grade components & latest technology. Our product is available in several specifications so as to meet the needs of customers. It comes under into the AC Controller .

Features:

  • Display Hold Feature
  • LED Indications to observe the status
  • Require less maintenance

Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 1,500 / Unit/Onwards
Get Best Quote
Over the years, we have been appreciated and acclaimed in the market in offering a wide array of 2 A/C Controller With GSM. Our AC controllers are featured with simple 5 Key keypad for onsite programming, automatic timer mode operation if room sensor fails & separate outputs for each fan and compressor. Offered AC controllers are tested on numerous parameters before dispatching at customer’s end. In addition to this, we offer these AC controllers as per specific requirements of patrons at affordable prices.

Features:

  • Fully programmable
  • Complete protection for AC from unhealthy condition
  • All set points programmable from keypad
  • Password protection for controller

Specifications:

  • Fully programmable
  • Complete protection for AC from unhealthy condition
  • All set points programmable from keypad
  • Password protection for controller
  • Different Passwords for Normal set points, Offset Set points
  • 16 character & 2 lines LCD display with back lit on controller front panel
  • Simple 5 Key keypad for on site programming
  • Separate alarm contacts for AC 1 fail alarm AC 2 fail alarm, power fail
  • Protection of Compressor from High Pressure, Low Pressure
  • Automatic display of AC parameters one by one in Run Mode
  • Status & Healthy indication by LED on front panel
  • Alarm indication by LED on front panel
  • Room temperature sensing by precise sensor
  • Grill High/Grill Low sensing for each AC
  • PC connectivity via RS232 port
  • Separate outputs for each fan and compressor
  • Direct display of Line voltage & actual current drawn by compressor
  • Direct display of actual room temperature
  • Sequencing of comp. for equal run hours, Site selectable
  • Automatic Timer mode operation if Room sensor fails
  • All Faults Auto reset
  • Smoke fire sensing
  • Fault log History.(last 10 faults)
  • Compressor hour run 4 digit display
  • Time remaining for change over display
  • Total hour run from installation.
  • Each AC supply is protected by individual Miniature Circuit Breaker

Technical Specifications:



Supply Voltage:


  • 230 VAC ±15%
  • Independent Outputs for Fan & Compressor

Output Contact Rating:


  • 25 Amps. at 230 VAC for compressor
  • 10 Amps. at 230 VAC for Fans
  • 7 Amps. at 230 VAC for Alarms

Sensing:


  • Inbuilt Voltage & Current sensing for Compressor & fan
  • Temperature Sensing by precise Room Temperature & Grill Temp. Sensors

Terminals:


  • Separate o/ps for 2 Fans & 2 Compressors
  • Temperature sensor
  • AC1 fail alarm relay o/p
  • AC2 fail alarm relay o/p
  • Power fail alarm relay o/p

Alarms/Protections:


  • Over voltage protection set point user selectable
  • Under voltage protection set point user selectable
  • Over load protection set point user selectable
  • Underload protection set point user selectable
  • Automatic cut off for smoke/Fire
  • High/low temperature alarm set point user selectable
  • High/low Grill temperature alarm set point user selectable.
  • Compressor High Pressure Fault
  • Compressor Low Pressure Fault

Dimensions:

  • Controller: 425 mm X 325 mm X 130 mm

Yes! I am interested
REQUEST CALLBACK
Approx. Rs 1,500 / Unit
Get Best Quote
Introduction:

3 A/C Controller is most useful for controlling A/Cs. This instrument is able to maintain Room Temperature with an accuracy of 0.1°C by automatic measurement of Room temperature and accordingly controlling A/C ON/OFF. It also protects Costly Air conditioner from ‘Unhealthy conditions’ such as over load/under load etc. by automatically cutting off the load. It comes under into GSM Controller

Sensing:

  • Inbuilt Voltage & current sensing for compressor.
  • Temperature Sensing by precise Temp. Sensor.
  • Fire Alarm sensing.

Terminals :

  • Separate O/Ps for each Compressor.
  • Temperature sensor.
  • Alarm relay o/p.
  • Fire Sensor.

Alarms / Protections:

  • Over Voltage, Under voltage protection set points are user settable.
  • Overload, Under load protection set points are user settable.
  • High / low temperature alarm set point user settable.

Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 1,500 / Unit
Get Best Quote
Salient Features :

  • Controls two air conditioners.
  • Separate Phase Supply for each A/C
  • Bright Red 4 Digit LED Display
  • Accurate Temperature sensing by precise temperature sensor
  • Time Sharing for Compressors to share load equally
  • Voltage & Current protections for each compressor
  • Separate alarm relay contacts for AC Fail
  • Fire protection by Digital Input
  • Hour counters for Compressor On Period to check its reliability
  • Display of all the A/C parameters & fault messages continuously in a scrolling manner
  • Display Hold Feature by using Enter Key. Press it again to release the hold.
  • Various set points are settable through the following different Menu categories :

 

  1. View
  2. Set
  3. Reset

 

  • Password Protection for all the settings
  • Sensor Fail Mode to keep On & Off cycle of one of the A/C through sensor fail On/Off time settings
  • Auto (with all protections)/manual (without protection) Modes
  • Controller Bypass feature by provision of Switch on Front Panel
  • LED Indications to observe the status

Technical Specifications:

  • Supply Voltage: 230VAC, 50Hz +/-15% separate for each A/C OR 3 Phase 415VAC, 50Hz +/- 15% separate for each A/C
  • Contact Rating: 30A at 230VAC for Compressor Live Outputs & 5A at 250VAC for Alarm Potential Free Outputs (C, N/O)
  • Temperature Sensor: Thermistor Sensor NTC 10K @ 25C Metal body with clamp
  • Sensor Cable Length: 2.75 meters
  • Temperature Sensing Range: 0.0C to 55.0C
  • Resolution: 1V for Voltage, 0.1A for Current & 0.1C for temperature
  • Auto / Controller Bypass Switch: To bypass the controller i.e. A/C1 & A/C2 will remain On. Continuously if both the switches are in On condition

Yes! I am interested
REQUEST CALLBACK
Approx. Rs 1,500 / Unit/Onwards
Get Best Quote
Air conditioning systems are vitally needed by Cell sites, offices etc. The heart of an Air conditioner is its compressor hence some protection means must be provided to the compressor to protect it from abnormal conditions such as Over voltage, Under voltage, Over Loading, etc. The efficiency of an Air conditioner depends on its Compressor. The compressor cause problems due unhealthy conditions such as Over voltage, Under voltage etc. & frequent start/stop without prior time delay for pressure equalization. To take care of A/C from such electrical hazards ‘PROTON ELECTRONICS’ has developed a new innovative product “AC GUARD.” AC GUARD is a Microprocessor based system that controls operation A/C & also protect it from electrical hazards. It also indicate respective faults by messages & LED on front panel. All the set points such as Voltage, Current, Temperature are site selectable & user can easily set them by using keys provided on the front panel.

SALIENT FEATURES:-

  • Controls/ Protects one Air conditioner.
  • Protection against Over voltage, Under Voltage, Over Load, Under load , with Alarm indication.
  • 3 Digit LED display to view Temperature, Voltage, Current & Set points.
  • Over voltage, under voltage, Over current, Temperature set point, Hysterisis of temperature, ON Time, OFF Time are user settable.
  • Low power consumption.
  • AC ON indication by LED on front panel.
  • Separate alarm contacts for power fail & AC fail alarms

Technical Specifications:-

  • System Supply : 230 VAC +/- 15%
  • Output Contact Rating : Output contact rating for AC 25 A at 230 VAC
  • Power On Delay time : 1 minutes
  • Restart Delay time : 3 minutes
  • Trip time delay : 3 sec for UV & OV , 5 sec. OL & 5 minutes for UL
  • Over voltage : Default 260 V .User settable by keys. , 10 V hysterisis between Cutoff & Cut in. Auto reset

Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 1,500 / Unit
Get Best Quote
We provide high quality & accurate Sensicool Controller & Spacemaker which are widely recognized among our clients.

Salient Features Of Sensicool Controller:

  • Controls two air conditioners
  • Separate Phase Supply for each A/C
  • Bright Red 4 Digit LED Display
  • Accurate Temperature sensing by precise temperature sensor
  • Time Sharing for Compressors to share load equally
  • Voltage & Current protections for each compressor
  • Separate alarm relay contacts for AC Fail
  • Fire protection by Digital Input
  • Hour counters for Compressor ON Period to check its reliability
  • Display of all the A/C parameters & fault messages continuously in a scrolling manner
  • Display Hold Feature
  • Password Protection for all the settings
  • Sensor Fail Mode to keep On & Off cycle of one of the A/C through sensor fail On/Off time settings
  • Auto (with all protections)/Manual (without protection) Modes
  • Controller Bypass feature by provision of Switch on Front Panel
  • LED Indications to observe the status


Technical Specifications


Supply Voltage :230 VAC, 50 Hz /- 15% separate for each A/C.
Contact Rating:30 Aat 230 VACfor CompressorLive Outputs&
5 A at 250 VAC for AlarmPotential FreeOutputs(C,N/O)
Temperature Sensor:Thermistor Sensor NTC 10K@25ºC Metal body with clamp.
Sensor Cable Length: 2.75 meters
Temperature Sensing Range:0.0º º C to 55.C
Resolution :1V for Voltage, 0.1 A for Current & 0.1ºC for temperature.
Auto/Controller Bypass Switch:To bypass the controller i.e. A/C1 &A/C2 will remain ON
continuously if both the switches are in ON condition.
Indications:1] SupplyON for A/C1 &A/C2. Colour: Yellow
2] Auto Mode for A/C1 &A/C2 Colour: Green
3] Manual Mode for A/C1 &A/C2 Colour: Red
4] AC ON for A/C1 &A/C2 Colour: Green
5] Fault for for A/C1 &A/C2 Colour: Red
6] Room High Colour: Red
7] Healthy Colour: Green
Keys: 4 key keypad for settings.1] SET Key: To enter into SET Mode/To view the next set point
2] Up Arrow Key : To increment the set point/To view next menu/To view next set point inVEW menu.
3] Down Arrow Key: To decrement the set point/To view previous menu/To view previous set point in VEW menu.
4] ENTER Key: To come out of SET mode/To enter into menu/To accept the password
Mounting :Flush mounting


Yes! I am interested
REQUEST CALLBACK
Approx. Rs 1,500 / Unit/Onwards
Get Best Quote
Supply Voltage :

  • 230 VAC ± 15 % for Single Phase
  • 415 VAC ± 15% for Three Phase
  • Separate power supplies for each AC &
  • independent Outputs for Fan & Compressor

Output Contact Rating : 25 Amps. at 230 VAC

Front Panel :

  • 16 char. 2 lines LCD display with backlit.
  • 4 Key keypad for programming.
  • Power indication for each AC.
  • AC ON indication for each AC
  • Controller Healthy Indication by Blinking Green LED
  • ALARM indication by Red LED.

Sensing :

  • Inbuilt Voltage & Current sensing in Power supply unit for compressor.
  • Temperature Sensing by precise Temp.sensor

Dimensions :
  • Controller : 245 mm X 150 mm X 60 mm
  • Power supply unit:-125mm X 68mm X168mm

Terminals

  • Power unit for each AC, separate o/ps for 2 Fans & Compressor
  • Temperature sensor
  • AC1 fail alarm relay o/p.
  • AC2 fail alarm relay o/p
  • Power fail alarm relay o/p

Alarms/ Protections :

  • Over voltage protection set point user selectable.
  • Under voltage protection set point user selectable.
  • Over load protection set point user selectable.
  • Under load protection set point user selectable.
  • Automatic cut off for smoke/Fire.
  • High/low temperature alarm set point user selectable.

Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 1,500 / Unit/Onwards
Get Best Quote
MODEL: ACC-02 (1P) ,ACC-02 (3P)
  • Supply Voltage:
    230 VAC ± 15 % for Single Phase 415 VAC ± 15% for Three Phase Separate power supplies for each AC & independent Outputs for Fan & Compressor
  • Output Contact RatingPer A/C :
    1] Single Phase : a] 25 Amps. at 230 VAC for Compressor Output
    b] 7Amps. at 230V AC for fan & alarm outputs.
    2] Three Phase : a] 9 Amps. at 230 VAC 3 Phase Contactor for Compressor Output
    b] 7Amps. at 230V AC for fan & alarm outputs.
  • Front Panel : .
    1) 16 char X 2 lines LCD display with backlit.
    2) 4 Key keypad for programming.
    3) Power indication for each AC.
    4) AC ON indication for each AC
    5) Controller Healthy Indication by Blinking Green LED
    6) ALARM indication by Red LED.
  • Sensing :
    1) Inbuilt Voltage & Current sensing in Power supply unit for compressor.
    2) Temperature Sensing by accurate Temp.sensor. 3) Fire Input Sensing
    4) DG Mode Sensing
  • Terminals : .
    1) Power unit for each AC, separate o/ps for 2 Fans &2 Compressors.
    2) Temperature sensor.
    3) AC1 fail alarm relay o/p.
    4) AC2 fail alarm relay o/p.
    5) Power fail alarm relay o/p
  • Alarms/ Protections : 1) Over voltage protection set point user settable.
    2) Under voltage protection set point user settable.
    3) Over load protection set point user settable.
    4) Under load protection set point user settable.
    5) Automatic cut off for smoke/Fire.
    6) High/low temperature alarm set point user selectable.
  • Power Supply unit : for 3PN & 1 Ph Supply
  • Dimensions : .
    1) Controller : 245 mm X 150 mm X 60 mm
    2)Power supply unit:-125mm X 68mm X168mm

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    Having a definite quality management system, we are regarded as the noteworthy firm of an extensive gamut of Dual AC Controller. Our offered AC controller is developed with excellent grade material keeping in mind the market norms. This AC controller is capable of controlling two Air Conditioners at a time. As well, this AC controller is provided with separate Phase supply for both the ACs and control by pass features too.

    Features:

    • Display Hold Feature
    • Password Protection for all the settings
    • LED Indications to observe the status

    Indications:

    • Supply ON for A/C 1 & A/C 2: Colour: Yellow
    • Auto Mode for A/C 1 & A/C 2: Colour: Green
    • Manual Mode for A/C 1 & A/C 2: Colour: Red
    • A/C 1 & A/C 2 ON: Colour: Green
    • A/C 1 & A/C 2 Fault: Colour: Red
    • Room High: Colour: Red
    • Healthy: Colour: Green

    Specifications:

    • Model: Dac-1
    • Supply Voltage: 230V AC, 50 Hz /- 15% separate for each A/C.
    • Contact rating: 30 A at 230 V AC for compressor Live Outputs & 5 A at 250 V AC Alarm Potential free outputs(C, N/O)
    • Temperature Sensor: Thermistor sensor NTC 10K @ 25 C metal body with clamp. Sensor cable length 2.75 meters.
    • Temperature Sensing Range: 0 - 55C
    • Resolution: 1 V for voltage, 0.1 A for Current & 0.1 degree C for Temperature.
    • Auto/Controller Bypass Switch is used to bypass the controller i.e. A/C 1 & A/C 2 will remains ON(irrespective of temperature demands) if both switches are in ON condition.

    Yes! I am interested
    REQUEST CALLBACK
    Ask Latest Price
  • Supply Voltage:230 V AC, 50 Hz 15% separate phases for each A/C.
  • Contact Rating: 30 A at 230 V AC for Compressor Live Outputs & 5 A at 250V AC for Alarm Potential Free Outputs (C,N,O)
  • Temperature Sensor: Thermistor Sensor NTC 10K@25C Metal body with clamp Sensor Cable Length: 2.75 meters
  • Temperature Sensing Range: 0.0C to 55.0 C
  • Resolution: 1V for Voltage, 0.1 A for Current & 0.1C for temperature.
  • Indications:
    1) Supply ON for A/C1 & A/C2, A/C3. Colour: Yellow
    2)OV/UV Fault Colour: Red
    3) Sensor Fail fault Colour: Red
    4) Room temperature High fault Colour: Red
    5) Healthy Colour: Green
    6) Keys: 4 key keypad for settings. 1] SET Key : To enter into FUNCTION SET Mode/To view the next set pt. 2] Up Arrow Key : To increment the set point
    3] Down Arrow Key: To decrement the set point.
    4] ENTER Key: To come out of FUNCTION SET mode/To enter into menu/To
    accept the password
    7) Mounting : Wall mounting
    8) Size : 245 mm (H) X 235 mm (W) X 67 mm (D
  • Mounting:Wall mounting

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit
    Get Best Quote
    MODEL: ACC-02-06 (1P) 4AC
  • Supply Voltage: 230 V AC, 50 Hz 15% separate Phase for each A/C.
  • Contact Rating: 30 A at 230 V AC for Compressor Live Outputs & 7 A at 250 V AC for Alarm Potential Free Outputs (C, N,O )
  • Temperature Sensor: Thermistor Sensor NTC 10K@25C Metal body with clamp Sensor Cable Length: 2.75 meters
  • Temperature Sensing Range: 0.0C to 55.0 C
  • Resolution: 1V for Voltage, 0.1A for Current & 0.1C for temperature.
  • Indications:
    1] Supply ON for A/C1 & A/C2, A/C3 & A/C4. Colour: Yellow
    2] OV/UV Fault Colour: Red
    3] Sensor Fail fault Colour: Red
    4] Room High fault Colour: Red
    5] Healthy Colour: Green
  • Dimensions: 245 mm (W) X 235 mm (H) X 67 mm (D)
  • Keys: 4 key keypad for settings.
    1] SET Key: To enter into FUNCTION SET Mode/To view the next set point
    2] Up Arrow Key: To increment the set point
    3] Down Arrow Key: To decrement the set point.
    4] ENTER Key: To come out of FUNCTION SET mode/To enter into menu/To accept the password.
  • Mounting:Wall mounting

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    Model: UF_FC1
  • Aux. Supply: 48V DC
  • Input Supply Voltage: 230 VAC ± 15 %
  • Outputs:
    Fan : 0-10V DC
    Compressor : 230 VAC ± 15
    Damper : 48V DC
  • Front Panel:
    1) 16 char. 2 lines LCD display with backlit.
    2) 5 Key keypad for programming.
  • Sensing:
    1) Inbuilt Voltage & current sensing in Power
    2) Temperature Sensing by precise temp. sensor.
    3) Tacho input from Fan
    4) High Pressure/Low Pressure sensing for compressor
  • Terminals :
    1) Compressor Output
    2) Damper Output.
    3) Temperature sensor.
    4) AC alarm relay o/p.
    5) Room High alarm relay o/p.
    6) Fan Supply Output (0-10V DC)
  • Network Connectivity:
    1) RS-485 Modbus RTU
    2) LAN
  • Alarms/ Protections:
    1) OV/UV protection set point user Selectable.
    2) OL/UL protection set point user Selectable.
    3) High/low temperature alarm set point user selectable.
  • Dimensions: 150 mm x 200 mm x 80(H x W x D)

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    MODEL: ACC-50
  • System Supply: 230 VAC /- 15%
  • Output Contact Rating: Output contact rating for AC 25 A at 230 VAC
  • Power On Delay time: 1 minutes
  • Restart Delay time: :3 minutes
  • Trip time delay: 3 sec for UV & OV, 5 sec. OL & 5 minutes for UL
  • Over voltage: Default 260 V .User settable by Keys. 10 V hysteresis between Cutoff & Cut in. Auto reset
  • Under voltage: Default 180 V User settable by keys. 10 V hysteresis. Auto reset.
  • Over Load: Default 15 A. User settable by keys.
  • Under Load: Default 3 A user settable. Make it 0 A to bypass UL protection
  • Cycle Time: 240 min.
  • Indications:
    1) Healthy: Indicates controller is working healthy.
    2) ALARM: when this LED glows it indicates presence & fault.
    3) AC ON: when this LED glows it shows AC is ON

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit
    Get Best Quote
    MODEL: ACC-45
  • System Supply : 230 VAC /- 15%
  • Output Contact Rating : Output contact rating for AC 25 A at 230 VAC
  • Power On Delay time : 1 minutes
  • Restart Delay time:3 minutes
  • Trip time delay : 3 sec for UV & OV , 5 sec. OL & 5 minutes for UL Low lube oil pressure Fire n alternator fault
  • Over voltage : Default 260 V .User settable by keys. 10 V hysteresis between Cutoff & Cut in. Auto reset
  • Under voltage : Default 180 V User settable by keys. 10 V hysteresis. Auto reset.
  • Over Load: Default 15 A. User settable by keys.
  • Under Load : Default 3 A user settable. Make it 0 A to bypass UL protection
  • ON Time :Default 60 min. User settable by keys
  • OFF Time: Default 30 min. User settable by keys
  • Indications:
    1.Healthy: Indicates controller is working healthy.
    2. ALARM : when this LED glows it indicates some fault is present.
    3 . AC : when this LED glows it shows AC is ON

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
  • Supply:3 Phase 4 wire 415 VAC, 50 Hz.
  • Display: 16*2 LCD Display for status & Faults.
  • Input: MCB TPN 32 Amp, 10 KA capacity.
  • Output: 40Amp single pole contactor for each A/C (230VAC) for ALARM contact.
  • Alarm O/P: 2 Nos. Alarm contacts @ 7Amp A/C.(250VAC)
  • Sensor:NTC Temp sensor for room Temp. (Range 0 - 55°C)
  • Fire input:Fire alarm input from fire panel.
  • Indications:
    1. Healthy indication for controller.
    2. A/C ON indication for each A/C.
    3.Alarm indication 2 no’s: AC Alarm, Fire Alarm.
  • Front Panel:
    1] 16 char. 2 lines LCD display with backlight.
    2] 4 Key keypad for programming.
    3] A/C1 ON indication.
    4] A/C2 ON indication.
    5] Healthy Indication by blinking Green LED.
    6] ALARM indication by Red LED.
  • Terminals :
    1] Separate O/Ps for each Relay.
    2] Temperature sensor.
    3] Fire Sensor.
    4] Alarms relay o/p.
  • Alarms/ Protections:
    1] Over Load protection set point user settable.
    2] Under Load protection set point user settable.
    3] High/low temperature alarm set point user settable.

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    GSM Connectivity available , Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply: 415 VAC(R, Y, B, N), 50Hz
  • Display: 16*2 LCD Display for status & Faults.
  • Input: 3 Phase 415 VAC, 50 Hz (R, Y, B & N) (No auxiliary supply).
  • Output: 40Amp 3 pole contactor for each A/C (230VAC) for ALARM contact.
  • Alarm O/P: 2 Nos. Alarm contacts @ 7Amp A/C.
  • Sensor: NTC Temp sensor for room Temp.(Range 0 - 55C)
  • Indications: 1) Healthy indication for controller.
    2) A/C ON indication for each A/C.
    3) Alarm indication 2 nos: AC Alarm, Fire Alarm.
  • Front Panel:1] 16 char. 2 lines LCD display with backlight.
    2] 4 Key keypad for programming.
    3] A/C1 ON indication.
    4] A/C2 ON indication.
    5] Healthy Indication by blinking Green LED.
    6] ALARM indication by Red LED.
  • Sensing: 1] Inbuilt voltage sensing for Relay.
    2] Inbuilt Currant sensing for Relay.
    3] Temperature sensing by precise Temp. Sensor.
  • Terminals : 1] Separate O/Ps for each AC.
    2] Temperature sensor.
    3] Alarms relay o/p.
  • Alarms/ Protections: 1] Over voltage protection set point user settable.
    2] Under voltage protection set point user settable.
    3] SPP voltage protection with disable allows.
    4] Unbalance voltage protection set point user settable with disable allow.
    5] RP voltage protection with disable allows.
    6] Over Load protection set point user settable.
    7] Under Load protection set point user settable.
    8] Load Unbalance protection set point user settable with disable allows.
    9] High/low temperature alarm set point user settable.

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit
    Get Best Quote
  • Input Supply: 230VAC /- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs.
  • Protections: Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V
  • O/P Contacts: O/P contact for both A/C 2
  • Indications: A/C1 ON, A/C2 ON, ON Delay, Over voltage (OV) trip, Under voltage (UV) Trip, Manual Mode, Auto Mode.
  • ON Delay Time : 2 minute & 30 sec
  • Change over time delay : 4/8 Hr ( site selectable switch)
  • O/P Contacts Rating : 30 amps At 230 VAC
  • Dimension: 85(W) X 190 (L)
  • Working:
    1. If Auto/Man switch is in Auto mode & Test/Timer switch is in Timer position then each A/C runs for Hrs. which is selected by user.
    2. If Auto/Man switch is in Auto mode & Test/Timer switch is in Test position then both A/C runs for Hrs. which is selected by user.
    3. If Auto/Man switch is in Manual mode then A/C will be ON which is selected by third DIP switch. It will be continuously ON.
  • Mounting: Wall Mounting

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    Model: Comp1AC , Comp2AC
  • System Supply: 230 VAC /- 15%
  • Output : contact rating for AC 25 A at 230 VAC
  • Power On Delay time: 5 sec
  • Restart Delay time: 5 sec
  • Size: 55mm x 65mm x 125mm
  • INDICATIONS:
    1) Alarm :OverLoad ,OV (Over Voltage) ,UV (Under Voltage) :indicates present & fault
    2) AC 1 ON , AC 2 ON : Corresponding AC is ON

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    MODEL: TT-2
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply: Single phase 230 VAC, 50 Hz.
  • Display: 16 X 2 LCD Display for Status & Faults.
  • Output: 30 Amps. At 250 V AC for A/C Contacts,
  • Alarm O/P: 2 Nos. Alarm contacts @ 7A 250V AC
  • Sensor: NTC Temp. Sensor for room temp (Range 0 - 55C)
  • Fire Alarm: Fire Alarm input from Fire Panel
  • Indications:
    1) Healthy indication for controller.
    2) A/C ON indication for each A/C.
    3) Alarm indication 2 no’s: AC Alarm, Fire Alarm.
  • Dimensions: 330 (W) X 220 (H) X 80 (D)
  • Front Panel:
    1) 16 X 2 LCD display with backlight.
    2) Key keypad for programming.
    3) A/C1 ON indication.
    4) A/C2 ON indication.
    5) Healthy Indication by blinking Green LED.
    6) ALARM indication by Red LED.
    7) FUN,INC,DEC,ENT keys for parameter setting.
  • Sensing:
    1) Inbuilt Voltage sensing for compressor.
    2) Temperature sensing by Accurate Temp. Sensor
    3) Fire Alarm sensing.
  • Terminals :
    1) Separate O/Ps for each Compressor.
    2) Temperature sensor.
    3) Alarm relay o/p.
  • Alarms/ Protections:
    1) Over Voltage protection set point user settable.
    2) Under Voltage protection set point user settable.
    3) High/low temperature alarm set point user settable.

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    MODEL: TT-3
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply: Single phase 230 VAC, 50 Hz.
  • Display: 16 X 2 LCD Display for status & Faults.
  • Output: 30 Amps. At 250 V AC for A/C Contacts,
  • Alarm O/P: 2 Nos. Alarm contacts @ 7A 250V AC
  • Sensor: NTC Temp. Sensor for room temp ( Range 0 - 55C)
  • Fire Alarm: Fire Alarm input from Fire Panel
  • Indications:
    1) Healthy indication for controller.
    2) A/C ON indication for each A/C.
    3) Alarm indication 2 nos: AC Alarm, Fire Alarm.
  • dimension: 330 mm (W) X 220 mm (H) 80 mm (O)
  • Front Panel:
    1) 16 char X 2 lines LCD display with backlight.
    2) Key keypad for programming.
    3) A/C1 ON indication.
    4) A/C2 ON indication.
    5) A/C3 ON indication.
    6) Healthy Indication by blinking Green LED.
    7) ALARM indication by Red LED.
    8) FUN,INC,DEC,ENT keys for parameter setting.
  • Sensing:
    1) Inbuilt Voltage sensing for compressor.
    2) Temperature sensing by precise Temp. Sensor.
    3) Fire Alarm sensing.
  • Terminals ::
    1) Separate O/Ps for each Compressor.
    2) Temperature sensor.
    3) Alarm relay o/p.
  • Alarms/ Protections:
    1) Over Voltage protection set point user settable
    2) Under Voltage protection set point user settable.
    3) High/low temperature alarm set point user settable.

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    MODEL: TT-4
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply: Single phase 230 VAC, 50 Hz.
  • Display: 16 x 2 LCD Display for status & Faults.
  • Output: 30 Amps. At 250 V AC for A/C Contacts
  • Alarm O/P: 2 Nos. Alarm contacts @ 7A 250V
  • Sensor: NTC Temp. Sensor for room temp (Range 0 - 55C)
  • Fire Alarm: Fire Alarm input from Fire Panel
  • Indications:
    1) Healthy indication for controller.
    2) A/C ON indication for each A/C.
    3) Alarm indication 2 nos: AC Alarm, Fire Alarm
  • Dimensions: 330mm(W) X 220 mm (H) X 80 mm (O)
  • Front Panel:
    1) 16 char. 2 lines LCD display with backlight.
    2) Key keypad for programming.
    3) A/C1 ON indication.
    4) A/C2 ON indication.
    5) A/C3 ON indication.
    6) A/C4 ON indication.
    7) Healthy Indication by blinking Green LED.
    8) ALARM indication by Red LED.
    9) FUN,INC,DEC,ENT keys for parameter setting.
  • Sensing:
    1) Inbuilt Voltage sensing for compressor.
    2) Temperature sensing by precise Temp. Sensor.
    3) Fire Alarm sensing.
  • Terminals :
    1) Separate O/Ps for each Compressor.
    20 Temperature sensor.
    3) Alarm relay o/p.
  • Alarms/ Protections:
    1) Over Voltage protection set point user settable.
    2) Under Voltage protection set point user settable.
    3) High/low temperature alarm set point user settable.

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    5AC Controller
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply: 3 Phase 4 wire 415 V AC, 50Hz.
  • Display: 16 x 2 LCD Display for Status & Faults.
  • Input: MCB TPN 32Amp, 10KA capacity.
  • Output: 30 Amp single pole contactor for each A/C (230 V AC)
  • Alarm O/P: 5 Nos. Alarm contacts @ 7 Amp 250VAC.
  • Sensor: NTC Temp sensor 1 No for room temp. (Range 0 - 55°C)
  • Fire Input: Fire alarm input from fire panel
  • Indications
    1) Healthy indication for controller.
    2) A/C ON indication for Each A/C.
    3) Alarm indications 5 Nos.
  • Dimensions: 330mm(W) X 220 mm (H) X 80 mm (O)
  • Keys: 4 key keypad for settings.:
    1) SET Key: To enter into FUNCTION SET Mode/To view the next set pt.
    2) Up Arrow Key: To increment the set point
    3) Down Arrow Key: To decrement the set point.
    4) ENTER Key: To come out of FUNCTION SET
    Mode/To enter into menu/To accept the password
  • Mounting: Wall mounting
  • Sensing: 1. Inbuilt current sensing for compressor.
    2. Temperature Sensing by precise Temp. Sensor.
    3. Fire Alarm sensing.
  • Terminals:
    1) Separate O/P s for each Compressor.
    2) Temperature sensor.
    3) Alarm relay o/p.
  • Alarms/ Protections:
    1) Over load protection set point user settable.
    2) Under load protection set point user settable.
    3) High/low temperature alarm set point user settable.

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    MODEL: TT-6
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply Voltage : 415 VAC ± 15 %( R, Y, B, N).
  • Output Contact Rating:
    30 Amps. At 250 V AC for A/C contacts.
    7 Amps. At 250 V AC for ALARM contact.
  • Front Panel:
    1)16 char. 2 lines LCD display with backlight.
    2) 4 Key keypad for programming.
    3) A/C1 ON indication.
    4) A/C2 ON indication.
    5) A/C3 ON indication.
    6) A/C4 ON indication
    7) A/C5 ON indication
    8) A/C6 ON indication.
    9) Healthy Indication by blinking Green LED.
    10) ALARM indication by Red LED.
  • Sensing:
    1)Inbuilt voltage sensing for compressor.
    2) Temperature sensing by precise Temp. Sensor.
    3) Fire Alarm sensing.
  • Terminals:
    1) Separate O/Ps for each Compressor.
    2) Temperature sensor.
    3) Alarm relay o/p.
  • Alarms/ Protections:
    1) Over voltage protection set point user settable.
    2) Under voltage protection set point user settable.
    3) High/low temperature alarm set point user settable

  • Yes! I am interested
    REQUEST CALLBACK
    Approx. Rs 1,500 / Unit/Onwards
    Get Best Quote
    MODEL: TT-7
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply Voltage: 250 VAC - 15 %
  • Output Contact Rating: 30 Amps at 250 V contacts.
  • Front Panel: 16 char. x 2 lines LCD display with backlight.
    4 Key keypad for programming.
    A/C1 ON indication.
    A/C2 ON indication.
    A/C3 ON indication.
    A/C4 ON indication.
    A/C5 ON indication.
    A/C6 ON indication.
    A/C7 ON indication.
    Healthy Indication by Green LED.
    ALARM indication by Red LED.
  • Dimensions: 330mm(W) X 220 mm (H) X 80 mm (O)
  • Sensing: High Pressure(HP)/ Low Pressure(LP) sensing for every AC.
    Temperature sensing by precise Temp. Sensor.
    AHU fault sensing.
  • Terminals:Separate O/Ps for each Compressor
    HP/LP input for each A/C.(It should be potential free)
  • Alarms/ Protections: High Pressure/Low pressure Alarm.
    High/low temperature alarm set point user settable.
    AHU fault Alarm.

  • Yes! I am interested
     
    X

    Download Brochure
    Proton Power Control Pvt Ltd.

    Abhijit Pawar (Director)
    Survey No. 28, Jagtap Dairy, Pimple Nilakh
    Pune - 411027
    Maharashtra, India
    Send Email
    © Proton Power Control Pvt Ltd.. All Rights Reserved (Terms of Use)