RO Plant Controller

Offering you a complete choice of products which include one phase pump starter panel, 3 phase over load relay, single phase overload relay controller and one phase pump panel.

REQUEST CALLBACK
Approx. Rs 2,000 / Unit/Onwards
Get Best Quote
We feel proud to announce ourselves as the leading manufacturer and exporter of One Phase Pump Starter Panel. This starter panel is tested in terms of quality for dispatching a defect free range. Offered starter panel is designed by our competent professionals using finest grade components & latest technology. Our starter panel is available in several specifications so as to meet the needs of customers.

Features:

  • Nominal Input Current: - 0-9 A
  • Accuracy: Current: - 0.25% ± 1 digits
  • Resolution: Current: - 0.01 A

Other Details:

  • Three digits 7 segment bright display for current
  • Calibration: using front keys
  • User Programmable
  • Password protected set parameters
  • Message Display for faults

Specifications :

  • Nominal Input Current: - 0-9 A
  • Accuracy: Current: - 0.25% ± 1 dgts
  • Resolution: Current: - 0.01 A

Environmental:

  • Working Temp : 0 to 55º C Storage Temp : 10 to 70º C Relative humidity: 0 - 95% non-condensing Warm up time : 10 Sec

Enclosure:

  • Mounting: Panel mounting. (Cut Out Size): 182(H) X 92(W)
  • Enclosure: 105 (W) X 200 (L) X 193 (H) mm.
  • Terminal: Screw On Terminals

Working:

  • In normal running mode, display shows
  • r-HP--Current r-rP--Current< Faults if any>
  • oL HP--Overload HPoL Rp--Overload Rp

Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 2,000 / Unit/Onwards
Get Best Quote
Assisted by our experienced professionals and truly skilled workers, we are able to offer a comprehensive range of 3 Phase Over Load Relay. These relays are developed by experts employing leading technology & best components as per the set norms of industry. Offered relays continuously display all three phase currents (if Display Current Enable) & faults (Over Load, current Unbalance & SPP) if present. These relays are checked by experts before dispatching at customer’s end.

Features:

  • Precisely engineered
  • Reliable operation
  • High functionality

Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 2,000 / Unit/Onwards
Get Best Quote
Single Phase Overload Relay Controller (OLR-1P)

The above 6 parameters are explained as follows :


  • Healthy: Power on
  • Alarm: Overload (OL), under voltage (UV), Over voltage (OV)
  • On: Pump Out, Pump relay on
  • Set Key: Set password, Enter in to setting parameter (OL, UV, OV, on delay, OL trip delay)
  • INC Key: It is used to set password & any setting parameters
  • DEC Key: It is used to set password & any setting parameters
  • Supply Voltage : 230 VAC ± 15 % for Single Phase input
  • Output Contact Rating: Pump Output relay 30 Amp. At 230V AC Pump Time Output relay 7 Amps At 230V AC (Potential Free)

Front Panel:

  • 3 digit, 7 segment LED display (Displays Voltage ‘U’, Current ’A’, Faults-Overload ‘oL’, Under voltage Over voltage)
  • Key keypad for programming. (SET, Increment, decrement)
  • Note: Decrement Key is also used for Fault Reset)
  • Led indications for controller
  • Healthy Indication by Blinking Green LED
  • Alarm indication by Red LED
  • Relay on indication by Green LED

Sensing:

  • Voltage sensing with resolution of 1V
  • Current sensing with 0.1A resolution

Alarm/Protections :

  • Over load protection set point user delectable 0.8Ato 30 A.
  • Over Voltage protection set point user selectable 240V to 290V.
  • Under Voltage protection set point user selectable 140V to 220V.
  • On delay set point user selectable 15s to 60s.
  • Over Load trip delay user selectable 1s to 30s.

Features:

  • Three digits 7 segment bright display for current.
  • Calibration: using front keys.
  • User Programmable.
  • Password protected set parameters.
  • Inbuilt 1 Phase 30 A Relay for load control.
  • Message Display for faults.

The Starter Panel has is solid state Current-Voltage Meters. It measures currents and provides protection against overload – Underload for both the motors. Voltage and Float & HP protection is available for both motors. LP fault is protecting motor

Dosing pump output is provided with motor 2. This is based on a Microchip, programmed for the application. The Meter’s supplied pre programmed for operation and can be directly installed.

Specifications:

Nominal Input Supply: - 10-270V AC.

Accuracy:

Voltage 0.25% ± 1 digits Current 0.25% rdg ± 1 digits

Environmental:

Working Temp : 0 to 55º C Storage Temp : 10 to 70º C condensing Relative humidity : 0 – 95 % non- Warm up time : 10 Sec

Enclosure :

  • Mounting : Panel mounting Cut Out Size: 182(H) X
  • 92(W)Enclosure : 105 (W) X 200 (L) X 193 (H) mm.Terminal : Screw on terminals

Working :

In normal running mode, display shows :

U -- Input Voltage

  • A1 -- Motor 1 Current
  • A2 -- Motor 2 Current

Faults if any :

  • OV-Over voltage
  • UV-Under voltage
  • OL1-Overload1
  • OL2-Overload2
  • UL1-Underload1
  • UL2-Underload2
  • LP-Low pressure
  • HP-High Pressure

If the supply is within the range and there is no fault condition, an ON timer starts decremented to zero and motor relay is turned on. After the motor is switched on, if any unhealthy condition occurs like OV, UV, OL, UL, LP, HP, float fault message display and after trip delay time the Relay is turned off. Fault message continuously display if the faulty condition persists. Posing pump relay is active only if motor.
Yes! I am interested
View PDF
REQUEST CALLBACK
Approx. Rs 2,000 / Unit/Onwards
Get Best Quote
Features:

  • Three digits 7 segment bright display for current.
  • Calibration: using front keys.
  • User Programmable.
  • Password protected set parameters.
  • Inbuilt 1 Phase 30 A Relay for load control.
  • Message Display for faults.

The Starter Panel has is solid state Current-Voltage Meters. It measures currents and provides protection against overload – Underload for both the motors. Voltage and Float & HP protection is available for both motors. LP fault is protecting motor

Dosing pump output is provided with motor 2. This is based on a Microchip, programmed for the application. The Meter’s supplied pre programmed for operation and can be directly installed.

Specifications:

Nominal Input Supply: - 10-270V AC.

Accuracy:

Voltage 0.25% ± 1 digits Current 0.25% rdg ± 1 digits

Environmental:

  • Working Temp : 0 to 55º C Storage Temp : 10 to 70º
  • Condensing Relative humidity : 0 – 95 % non- Warm up time : 10 Sec

Enclosure :

  • Mounting : Panel mounting Cut Out Size: 182(H) X
  • 92(W)Enclosure : 105 (W) X 200 (L) X 193 (H) mm.Terminal : Screw on terminals

Working :

In normal running mode, display shows :

U -- Input Voltage

  • A1 -- Motor 1 Current
  • A2 -- Motor 2 Current

Faults if any :

  • OV-Over voltage
  • UV-Under voltage
  • OL1-Overload1
  • OL2-Overload2
  • UL1-Underload1
  • UL2-Underload2
  • LP-Low pressure
  • HP-High Pressure

If the supply is within the range and there is no fault condition, an ON timer starts decremented to zero and motor relay is turned on. After the motor is switched on, if any unhealthy condition occurs like OV, UV, OL, UL, LP, HP, float fault message display and after trip delay time the Relay is turned off. Fault message continuously display if the faulty condition persists. Posing pump relay is active only if motor.